// SPECIFICATION MATRIX
Live Room Calibration Active

Session architectures and acoustic specifications

Surgical capture pathways configured for pristine solo definition, intimate chamber blend, and monumental orchestral sectional power.

ISO-BOOTH // ULTRA-DRYPLAYERS: 1 Soloist
Soloist tracking
Acoustic Isolation Booth A // RT60: 0.28s (Controlled Dry)

Tightly calibrated dry acoustics for lead violin, cello, woodwinds, and ethnic instruments. Delivers immaculate transient separation and pinpoint harmonic clarity without room bleed.

Acoustic & Delivery Delivery Standards

Direct stem separation
Receive zero-bleed, phase-aligned dry stems ready for your reverbs.
Articulations captured
Legato, spiccato, sul ponticello, harmonics, and custom expressive gestures.
Alternate takes
Three curated safety takes and one master composite take included per cue.

Dedicated Microphone & Signal Chain

Zero Latency Hardware Pass
01Coles 4038 Ribbon (Main Character)
02Neumann U67 Tube (Spot Detail)
03Focusrite ISA 110 Preamp Circuit
04Lavry Engineering AD122 Converters
24-BIT / 96KHZANALOG TAPE DISPATCH READY
Book this format
Acoustic Telemetry
REAL-TIME SPEC
BOOTH VOLUME
48 m³
Fully floated subfloor
SIGNAL-TO-NOISE
> 118 dB
A-weighted analog floor
MIC CHANNELS
4 Tracks
Spot + room + ribbon pair
SAMPLING
24-Bit / 96kHz
Lossless uncompressed
RT60 PROFILE DECAY0.28s (Controlled Dry)
0.1s (Ultra Dry)0.8s (Chamber)1.5s (Hall)
Validated Instrument Roster
Solo Violin (Baroque & Modern)Ready
Cello (C-Extension equipped)Ready
Woodwinds (Flute, Oboe, Clarinet)Ready
Erhu & Ethnic SoloistsReady
Classical & Acoustic GuitarReady
Need custom section size?Configure custom session
[ HARDWARE SPECIFICATION // CHAIN A ]

Preamplification, microphones, and conversion

Every acoustic transient captured in the live booth routes through transformer-coupled analog stages and master converters straight to your DAW.

Preamplification
MOD-01

Focusrite ISA Lundahl Core

Transformer-coupled discrete circuitry delivering pristine acoustic gain with open high-frequency air and tight low-end authority.

LUNDAHL LL1538THD+N < 0.0007%10HZ – 100KHZ
Input ArchitectureLundahl LL1538 Transformer
Frequency Response10Hz – 100kHz (+/- 0.1dB)
Variable Impedance600Ω / 1400Ω / 2400Ω / 6800Ω
EIN (Equivalent Noise)-128dBu at 60dB Gain
Direct DAW Sync: Sample-Accurate 64-bit Floating Bus
Microphone Locker
MOD-02

Matched Reference Microphones

Calibrated stereo pairs of ribbon transducers and precision condenser capsules positioned for natural orchestral transient fidelity.

COLES 4038ROYER R-121NEUMANN KM184 / U87
Master Conversion
MOD-03

Multi-Channel AD/DA Stage

Uncompromising 24-bit/192kHz multi-channel conversion clocked by femtosecond crystal oscillators for phase-accurate sample capture.

24-BIT / 192KHZ< 1PS JITTER131DB DYNAMIC RANGE
CALIBRATION: 0 VU = +4 dBu (1.228 Vrms) // HEADROOM: +24 dBu
CLOCK SOURCE: INTERNAL OCXO CRYSTALISOLATION: -110dB CROSSTALK